Home / GentleCardia / GentleCardia Specification
GentleCardia
Open infrastructure for human health.
GentleCardia is an open, modular specification for cardiac biosensing systems. Released under the GNU Affero General Public License v3.0 or later (AGPL-3.0+), the specification defines a standardized architecture for acquiring, processing, analyzing, and exchanging cardiac electrical signals while emphasizing patient safety, transparency, interoperability, and extensibility.
Rather than defining a single hardware device, GentleCardia establishes a reusable framework that hardware manufacturers, software developers, researchers, healthcare innovators, educators, and open-source communities can implement and extend. Every layer of the specification is modular, allowing implementations ranging from educational development boards to advanced research platforms and future clinical-grade systems.
Objectives
- Create an open cardiac biosensing infrastructure.
- Standardize ECG acquisition architectures.
- Promote transparent and reproducible biosignal processing.
- Encourage modular hardware and software ecosystems.
- Improve interoperability between devices.
- Enable AI-assisted cardiac research.
- Support privacy-first, local-first deployments.
- Eliminate vendor lock-in through open specifications.
- Encourage community-driven innovation.
- Prioritize safety-first engineering practices.
Design Principles
- Modular architecture
- Safety-first engineering
- Hardware independence
- Software interoperability
- Open communication standards
- Human-centered design
- Local-first operation
- Privacy by default
- AI-assisted, not AI-controlled
- Transparent processing pipelines
- Extensible specification ecosystem
- Long-term backward compatibility
Core Specification Modules
1. Sensor Acquisition Module
Defines standardized interfaces for cardiac signal collection.
Features
- 3-lead ECG support
- 5-lead ECG support
- Expandable multi-lead architectures
- Ag/AgCl electrode compatibility
- Dry electrode compatibility
- Lead impedance monitoring
- Electrode identification
- Lead-off detection
- Signal quality metrics
- Motion artifact detection
- Noise characterization
- Standardized connector definitions
2. Analog Signal Acquisition Module
Reference architecture for safe biopotential acquisition.
Features
- Instrumentation amplifier architecture
- High common-mode rejection
- Low-noise analog design
- Configurable gain stages
- Hardware filtering
- Right-leg drive support
- Input protection circuits
- ESD protection
- Patient isolation requirements
- Hardware diagnostics
- Calibration procedures
- Self-test capability
3. Digital Signal Processing Module
Defines standardized digital processing pipelines.
Features
- Configurable sampling rates
- 16-bit ADC support
- 24-bit ADC support
- Baseline wander removal
- Adaptive filtering
- Notch filtering
- Motion compensation
- Signal normalization
- Noise reduction
- Signal quality scoring
- Peak detection
- Waveform segmentation
4. Embedded Runtime Module
Provides real-time embedded operation.
Features
- Hardware abstraction layer
- Real-time scheduling
- DMA acquisition
- Interrupt management
- Power management
- Sleep modes
- Secure boot
- Firmware verification
- OTA update support
- Fault recovery
- Watchdog supervision
- Configuration management
5. Communication Module
Defines interoperable communication standards.
Features
- Bluetooth Low Energy
- USB
- UART
- SPI
- I²C
- Ethernet support
- Wi-Fi support
- Local network discovery
- Secure communications
- Device capability negotiation
- Standard messaging protocol
- Multi-device synchronization
6. Data Standardization Module
Provides portable cardiac data formats.
Features
- Open waveform formats
- Timestamp synchronization
- Metadata schemas
- Patient anonymization
- Event annotations
- Recording sessions
- Device metadata
- Signal provenance
- Calibration records
- Version compatibility
- Import/export standards
7. Visualization Module
Reference interfaces for waveform presentation.
Features
- Real-time ECG display
- Multi-lead visualization
- Historical playback
- Interactive measurements
- Annotation tools
- Signal overlays
- Trend graphs
- Zoom and pan
- Custom dashboards
- High-resolution rendering
8. AI Intelligence Module
Defines transparent AI integration.
Features
- QRS detection
- Heart rate calculation
- Heart rate variability
- Rhythm classification
- Signal anomaly detection
- Artifact classification
- Confidence scoring
- Explainable AI interfaces
- Human review workflows
- Local inference support
- Model interoperability
- AI audit logging
9. Security Module
Protects device integrity and data.
Features
- Secure boot
- Firmware signing
- Encrypted storage
- Encrypted communication
- Authentication
- Authorization
- Key management
- Audit logs
- Secure configuration
- Device identity
- Tamper detection
10. Safety Module
Defines patient protection requirements.
Features
- Battery-powered operation
- Electrical isolation guidance
- Current limiting
- Fault monitoring
- Lead failure detection
- Thermal monitoring
- Emergency shutdown
- Diagnostic self-tests
- Hardware validation
- Safety event logging
- Risk assessment framework
Optional Plug-in Modules
Implementations may include any combination of optional modules.
Wearable Module
- Chest straps
- Smart clothing
- Patch ECG
- Wearable power management
- Low-power optimization
Remote Monitoring Module
- Remote telemetry
- Home monitoring
- Caregiver dashboards
- Event notifications
- Offline synchronization
Clinical Research Module
- Research metadata
- Multi-subject studies
- Trial management
- Long-duration recording
- Protocol management
AI Research Module
- Machine learning datasets
- Federated learning
- Model benchmarking
- Explainability tools
- Synthetic signal generation
Developer SDK Module
- REST API
- C SDK
- C++ SDK
- Rust SDK
- Python SDK
- Java SDK
- JavaScript SDK
- WebAssembly SDK
Cloud Integration Module
- Hybrid deployments
- Distributed processing
- Secure synchronization
- Multi-device aggregation
- Cloud APIs
Mobile Module
- Android support
- iOS support
- Offline operation
- Local visualization
- BLE management
Educational Module
- Interactive tutorials
- Simulated ECG generation
- Training datasets
- Learning exercises
- Classroom deployments
Accessibility Module
- High-contrast interfaces
- Screen reader compatibility
- Keyboard navigation
- Configurable typography
- Color accessibility
Hardware Expansion Module
- Environmental sensors
- Pulse oximetry
- Respiration monitoring
- Blood pressure integration
- Temperature sensing
- IMU support
- Multi-sensor fusion
Future Specification Modules
The architecture is designed for future expansion.
Examples include:
- Digital Twin Module
- Predictive Health Module
- Biofeedback Module
- Rehabilitation Module
- Emergency Response Module
- Hospital Integration Module
- Edge AI Module
- Robotics Interface Module
- Medical Imaging Integration Module
- Multi-Biosignal Fusion Module
Reference Technology Stack
Hardware
- Open PCB reference designs
- Precision analog front ends
- 16–24 bit ADC architectures
- Low-power microcontrollers
- ARM Cortex-M support
- RISC-V support
- FPGA compatibility
- Isolated power systems
- Battery management systems
Firmware
- C
- C++
- Rust
- Embedded RTOS support
- Secure firmware updates
- Hardware abstraction layers
Software
- Python
- Rust
- C++
- JavaScript
- TypeScript
- WebAssembly
- Cross-platform desktop applications
- Browser-based visualization
Data
- JSON
- CBOR
- Protocol Buffers
- CSV
- EDF
- HDF5
- SQLite
- Time-series databases
Artificial Intelligence
- ONNX
- TensorFlow Lite
- PyTorch
- TinyML
- Explainable AI pipelines
- Federated learning
- Edge inference
Intended Applications
- Open-source ECG devices
- Educational laboratories
- Biomedical engineering
- Research platforms
- Wearable technologies
- Telehealth systems
- Human-computer interaction
- AI health research
- Remote patient monitoring
- Emergency response systems
Project Goals
GentleCardia aims to establish an open ecosystem for cardiac biosensing that enables collaboration across academia, industry, healthcare, and open-source communities. By defining interoperable standards instead of proprietary implementations, the specification encourages innovation while maintaining transparency, safety, and long-term sustainability.
Specification Branding License (SBL)
Standard
- Fully AGPL-3.0+ compliant system
- Copyleft enforced for network deployments
- Required attribution:
- Roxanne Ardary
- https://www.roxanneardary.com/
Optional
- Specification Branding License (SBL)
- Attribution-free commercial deployment
- Pricing based on scale, usage, and deployment scope
- https://roxanneardary.com/gentlecardia/
License & Notice Requirements
GentleCardia is released under the GNU Affero General Public License v3.0 or later (AGPL-3.0+).
By contributing to any Open Arsenal project, you agree that your contributions will also be released under this license.
Please note the following:
- All contributions must comply with the AGPL-3.0+ terms.
- Under Section 7 of the license, all redistributions, forks, and derivative works must preserve attribution to Roxanne Ardary and https://www.roxanneardary.com/.
- GentleCardia specifications are free to use with attribution. A Specification Branding License can be negotiated upon request.
- The project’s
notice.mdfile tracks attribution requirements and contributor acknowledgments. Any update that adds new contributors or modifies attribution should also updatenotice.md. - When submitting a pull request, ensure that any new files maintain the attribution headers where applicable.
- Network-deployed versions of this software must also remain fully AGPL-3.0+ compliant, including exposure of source code modifications when applicable under the license.
For full legal details, please refer to the AGPL-3.0+ license and the project’s notice.md file.
Notice – GentleCardia
Attribution Requirement: Under Section 7 of the AGPL 3.0+ license, all redistributions, forks, and derivative works, including network-deployed versions of this project, must provide attribution to Roxanne Ardary and roxanneardary.com.
Contributors
This file tracks contributors and their specific contributions to the project.
- Roxanne Ardary, roxanneardary.com – July 30, 2026
Created the GentleCardia repository and authored the open, modular AGPL-3.0+ specification defining a safety-first infrastructure for cardiac biosensing, signal acquisition, processing, interoperability, and future extensible health technologies. - [Add other contributors here] – [Date]
[Describe contribution in one sentence]
License – GentleCardia
This repository is licensed under the GNU Affero General Public License v3.0 or later (AGPL-3.0+).
Key Points:
- You are free to use, modify, and distribute the code.
- All redistributions, forks, and derivative works or network-deployed versions must also be licensed under AGPL-3.0+ and provide attribution to Roxanne Ardary and roxanneardary.com as required under Section 7 of the license.
- The software is provided “as is,” without warranty of any kind.
For the full license text, see GNU AGPL-3.0 License.